Transcranial Doppler Equipment
Model: LT-TCD-I TCD-II
Unique technical Characteristics
Multi-door is synchronous detection: Single-channel mode, one can simultaneously detect multiple 2HMz probe the depth of Doppler blood flow signals.
A single exposure can be displayed,you can also four window displays. Mwave mode to use the cash, so that doctors can be also observed under a single window over the depth of the Doppler signal, greatly improves the detection rate.
Multi-channel detection:
In the dual-channel mode, they can also detect patients at different depths on both sides of the Doppler signal, simultaneous display on both sides of the
four blocks of M-wave. Easy to do bilateral contrast. Intuitive convenience, saving a lot of time.
All information is stored:
System provides advanced full-information storage function, a complete record of the clinical testing information. A flexible testing process can reproduce, in a dynamic real-time playback mode to adjust the gain, envelope, manual calculation. The maximum to meet clinical needs.
Advanced M-wave mode:
Completely abandon the traditional model, in the 512-point FFT large image observation cases, be able to freely observe the Doppler signal over the depth,
arbitrary switching, handy.
High sensitivity:
Application of digital technology, makes 10% of the power, when, without ultrasound coupling agent,
the same can detect a clear pattern,
power adjustable freely, making detection of elderly patients with no problems.
Powerful case management:
The system provides a case database management system. May have the network transmission function (customer optional).
Probe into: Using the latest technology applications 4MHz continuous Doppler shift pulse Doppler
detection of extracranial blood vessels,
superficial blood vessels more accurate.
Report Editor: Based on the powerful
Word document editing, free editing, storage, access to and so on, the coexistence of a large number of diagnostic terminology, diagnosis.
Clinical Applications:
Clinical diagnosis:
Cerebral vascular stenosis and occlusion
Cerebral embolism
Vasospasm
Cerebrovascular atherosclerosis
Arteriovenous malformation
Migraine headache
HemorJHagic stroke, ischemic stroke
Intracranial aneurysm
Vertigo and vertebral-basilar artery disease diagnosis
Transient ischemic attack
Epidemiological study of brain blood vessel
Stroke prediction and the elderly health care
Technical Specification :
Operating system: Windows XP, Windows 7
Probe frequency:2Mhz Pw 4Mhz Cw
Spectrum scanning speed:4s-16s Arbitrarily set
Sampling volume (PW)0.77-13mm arbitrarily set
Gain Ranging:1-56dB
Investigation Depth:5mm-150mm(extend to 190mm)
Maximum detection speed: ≥ 300cm/s
Automatically detect the display index: Vp Vm Vd PI RI RYH S/D
Spectrum Display:512. 256 FFT
Supply power:220V±10% 50Hz±1Hz
Standard Configuration:
Mainframe
19-inch LCD display, Standard Keyboard,mouse
Software
English Windows-XP Operation Manual
Color Ink-jet Printer
2MHz PW probe
4MHz CW probe
Specialized Medical Trolley