Atomic Absorption Spectrophotometer 190-900nm Laboratory For Metal Element Analysis
Model: LTL-7800
The multi-media graphite furnace visual system can intuitively monitor the sample’s dynamic evolution during drying, ashing and residue burning process in the graphite tube. It enables convenient observation of the auto sampler’s capillary injection needle reaching the best position and depth in the tube, as well as the position of the platform placed in the graphite tube. It ensures analysis precision and graphite tube’s lifetime. |
♦Sensitive and Reliable
Electronic control of flame gas flow
Closed & isolated optical system
Suspension type of optical platform design
Power control of graphite furnace temperature programming
♦Flexible Configuration
Flame only, graphite furnace only, and combined flame & graphite furnace are available according to demand
One instrument has multifunctional configuration of flame, graphite furnace and hydride generator
6-lamp turret meets the requirement of multi-elements analysis
Complete optional accessories support the instrument’s upgrade and extension
♦Compact and Easy to Use
Stack design of combined flame and graphite furnace makes the system compact, 10 seconds to complete flame/graphite furnace switch
High-performance auto sampler conveniently and reliably improves laboratory efficiency
Intelligent EZPectrumTM workstation provides simple and easy-to-use user experience and laboratory standard requirements
♦Convenient Operation
National initiative visual system of atomization in graphite furnace
Dynamically monitor drying, ashing and atomization process
Intuitively control the depth and position of sampling
Perfectly demonstrate graphite furnace sampling
Flame Atomic Absorption Spectrophotometer
7800 Atomic Absorption Spectrophotometer is fully PC controlled. It can be flexibly equipped with optional graphite furnace, auto sampler, and hydride generator.
Unique optical mechanical design, safe and convenient flame system, optional background correction technologies, as well as convenient functions provided by the workstation, suit your pursuit of automatic and precise test results.
Main Features
♦ Compact and delicate appearance
♦ Convenient options of background correction method
♦ Unique optical design
♦ Perfect automation control is easily realized by using the software workstation
♦ Safe, reliable and convenient flame system
♦ Multifunctional software workstation
Specifications
6-lamp turret:
♦ Wavelength range: 190-900nm
♦ Wavelength indication error: ≤±0.3nm
♦ Wavelength repeatability: ≤0.15nm
♦ Photometric range: -0.1-2.5 (A)
♦ Spectral bandwidth: 0.1, 0.2, 0.4, 0.7, 1.0, 2.0nm
♦ Static baseline drift: ≤0.002ABS/30min(Cu)
♦ D2 background correction capability: ≥50 times when background signal =1A
♦ Self reversal background correction
♦ Power supply: AC220V±22V 50Hz±1Hz
Flame System
♦ Air/Acetylene burner head: 100mm
♦ Nitrous oxide /Acetylene burner head: 50mm
♦ Spray chamber: polypropylene coating
♦ Ignition dynamic baseline stability: ≤0.004ABS/30min(Cu)
♦ Characteristic concentration: ≤0.02μg / ml / 1%
♦ Repeatability : Cu≤0.5%;(Absorbance>0.8Abs)
♦ Detection limit: Cu≤0.004ug/ml
♦ Safety system: automatically cut off gas in case of low pressure, power failure, flame out, or burner mismatched.
Contact: LETY MEDICAL
Phone: +86 13802725767
Email: sales@letymedical.com
Add: A477/2F No.38 Industrial Zone, Shengtang Street, Cencun, TianHe District, Guangzhou