Atomic Absorption Spectrophotometer 190-900nm Laboratory For Metal Element Analysis
Model: LTL-5800
Main Features
♦ On the basis of 7800 AAS, considering commonly used functions, selectively keep some functions, highly cost effective.
♦ The instrument has good stability, wide measurement range, low detection limit, high resolution and high sensitivity
♦ Unique optical design greatly increases the sensitivity in visible range. The outstanding mechanical and optical system plus excellent software ensure measurement accuracy
♦ Rapid change of gas flow, grating rotation, slit and hollow cathode lamps
♦ Widely used in rare earth analysis, precious metal analysis, environmental protection, water quality inspection, alloy materials, construction materials, medicine and health, colleges and universities for quantitative analysis of elements
♦ Practical structure, simple operation, easy to master
♦ Fully satisfy the users who require flame analysis only
♦ Optional nitrous oxide is available. It expands measurement range and meets the demands from different areas.
Specifications
♦ Wavelength range: 190-900nm
♦ Grating: 1800lines/mm
♦ Wavelength repeatability: ±0.1nm
♦ Wavelength indication error: ±0.2nm whole range
♦ Optical system: Czerny-Turner, integrated optical platform, fully closed optical system
♦ Resolution: spectral bandwidth = 0.2nm, can separate Mn two lines(279.5nm and 279.8nm), valley/peak energy ratio<30%
♦ Spectral bandwidth: 0.1, 0.2, 0.4, 1.0nm
♦ Static baseline drift: ≤0.004ABS/30min(Cu)
♦ Background correction technology: D2 (background signal =1Abs, correction capability ≥50 times)
♦ Instrument design: integrating structure of suspended internal and external optical path
♦ Lamp turret: 4-lamp turret (4 lamps can preheat simultaneously)
♦ Burner head: air/acetylene (100mm, optional 50mm nitrous oxide/acetylene burner is available)
♦ Nebulizer: high-efficiency glass nebulizer
♦ Ignition dynamic baseline drift: ≤0.004ABS/30min(Cu)
♦ Characteristic concentration: Cu ≤0.025μg/ml/1%
♦ Detection limit: Cu≤0.008ug/ml
♦ Repreducibility: ≤0.5% ;(Cu, absorbance>0.8ABS)
♦ Gas flow control: manual
♦ Ignition: via buttons on the control panel
♦ Safety protection: automatically cut off gas in case of low pressure, power failure, flame out, or burner mismatched
♦ Background correction method: SR and D2, can correct 1A background. Background signal = 1A, correction capability ≥50 times
♦ Dimension: 700*550*530mm
5800 Atomic Absorption Spectrophotometer is a modified model based on 7800. It is an economical flame atomic absorption spectrophotometer with high performance, easy operation, accurate measurement and stable functions. It meets the requirement of limited budget and is well received by vast number of users.
Contact: LETY MEDICAL
Phone: +86 13802725767
Email: sales@letymedical.com