Hemotology Analyzer

  • Atomic Absorption Spectrophotometer 190-900nm Laboratory For Metal Element Analysis
Atomic Absorption Spectrophotometer 190-900nm Laboratory For Metal Element Analysis

Atomic Absorption Spectrophotometer 190-900nm Laboratory For Metal Element Analysis

  • Atomic absorption spectrophotometer
  • Elemental analysis
  • electronics learning lab
  • Product description: Atomic Absorption Spectrophotometer 190-900nm Laboratory For Metal Element Analysis
  • INQUIRY


 Atomic Absorption Spectrophotometer 190-900nm Laboratory For Metal Element Analysis

Model: LTL-5800

3.jpg

 

5800 Atomic Absorption Spectrophotometer is a modified model based on 7800. It is an economical flame atomic absorption spectrophotometer with high performance, easy operation, accurate measurement and stable functions. It meets the requirement of limited budget and is well received by vast number of users.

 

Main Features

♦ On the basis of 7800 AAS, considering commonly used functions, selectively keep some functions, highly cost effective.

 The instrument has good stability, wide measurement range, low detection limit, high resolution and high sensitivity

 Unique optical design greatly increases the sensitivity in visible range. The outstanding mechanical and optical system plus excellent software ensure measurement accuracy

 Rapid change of gas flow, grating rotation, slit and hollow cathode lamps

 Widely used in rare earth analysis, precious metal analysis, environmental protection, water quality inspection, alloy materials, construction materials, medicine and health, colleges and universities for quantitative analysis of elements

 Practical structure, simple operation, easy to master

 Fully satisfy the users who require flame analysis only

 Optional nitrous oxide is available. It expands measurement range and meets the demands from different areas.

 

Specifications

 Wavelength range: 190-900nm

 Grating: 1800lines/mm

 Wavelength repeatability: ±0.1nm

 Wavelength indication error: ±0.2nm whole range

 Optical system: Czerny-Turner, integrated optical platform, fully closed optical system

 Resolution: spectral bandwidth = 0.2nm, can separate Mn two lines(279.5nm and 279.8nm), valley/peak energy ratio<30%

 Spectral bandwidth: 0.1, 0.2, 0.4, 1.0nm

 Static baseline drift: ≤0.004ABS/30min(Cu)

 Background correction technology: D2 (background signal =1Abs, correction capability ≥50 times)

 Instrument design: integrating structure of suspended internal and external optical path

 Lamp turret: 4-lamp turret (4 lamps can preheat simultaneously)

 Burner head: air/acetylene (100mm, optional 50mm nitrous oxide/acetylene burner is available)

 Nebulizer: high-efficiency glass nebulizer

 Ignition dynamic baseline drift: ≤0.004ABS/30min(Cu)

 Characteristic concentration: Cu ≤0.025μg/ml/1%

 Detection limit: Cu≤0.008ug/ml

 Repreducibility: ≤0.5% ;(Cu, absorbance>0.8ABS)

 Gas flow control: manual

 Ignition: via buttons on the control panel

 Safety protection: automatically cut off gas in case of low pressure, power failure, flame out, or burner mismatched

 Background correction method: SR and D2, can correct 1A background. Background signal = 1A, correction capability ≥50 times

 Dimension: 700*550*530mm






CATEGORIES

CONTACT US

Contact: LETY MEDICAL

Phone: +86 13802725767

Email: sales@letymedical.com

Add: A477/2F No.38 Industrial Zone, Shengtang Street, Cencun, TianHe District, Guangzhou

Scan the qr codeClose
the qr code