  • Product description: HbA1c Analyzer Glycosylated hemoglobin Gold Standard of Diabetes Diagnose
  • INQUIRY


HbA1c Analyzer

Model:LTL-GH900

3.jpg

Glycosylated hemoglobin (HbAlc) is widely recognized as a Gold Standard to monitor diabetes, which can indicate the average plasma glucose concentration over 8-12 wecks.
GH1-900 HbAlc Analyser adopts 3-step chromatographic method, with patented result algorithm, to provide accurate result for clinical diagnose and treatment.

 

Specification
Methodology: lon Exchange Chromatography
28 Sample Positions
Test Range 3%-18%
5 Minutes to Get Result

 

 

Hemoglobin Analyzer HPLC High Performance Liquid Chromatography (HPLC)

Model:LTL-H9

1.jpg

4.jpg

5.jpg

 

 

 

Model: LTL-H8

 

Gold Standard of Diabetes Diagnose Glycosylated hemoglobin (HbA1c) is widely recognized as a Gold Standard to monitor diabetes, which can indicate the average plasma glucose concentration over 8 ~ 12 weeks. HPLC Methodology High-Pressure Liquid Chromatography (HPLC), to separate HbA1c directly with measuring the absorbance points continually to form chromatogram. Using normal distribution curve fitting auto-iterative algorithm to get precise HbA1c testing result, excluding interference of variant and unstable hemoglobin like HbF. Standard Analysis Mode will
report HbA1a, HbA1b, HbF, La1c, HbA1c, HbA0 peak areas and ratio. And the result also includes IFCC, NGSP and ADAG value for diverse client needs.

 

Methodology High - Performance Liquid Chromatography (HPLC)
Test Modes Standard Mode,Variant Mode,B- thalassemia Mode(Upcoming)
Test Range 3%-18%
Precision cV≤1.5%
First Sample Result 7.5 Mins
Test Speed 90 Secs / Sample for Fast Mode,130 Secs / Sample for Variant Mode
Sample Type Venous Blood,Finger Peripheral Blood,Lyophilized Whole Blood
Peripheral Blood, 50Oul ( 150 Dilution Ratio )
Auto Sample Station 10 Positions
Photometer 415nm + 500nm Detector
Chromatography Column Available Tests > 800T
Filter 400T
Display 10.1"TFT True Color LCD Touch Screen
Software Linux Software with Self - Diagnosis to Monitor and Detect System Errors
Reagent Kit Eluent A,Eluent B, Eluent C,Hemolysin, Calibrator,QC Material ( Weight Sensor±1%)
Information Input Scanner or Touch Keypad
Storage 4000 Sample Results
Connection usB,LAN,LlS Compatible
Printer Thermal Printer and External Laser Printer
operation Temperature 10~30℃( 50~86“F)
Humidity 8O%
Power AC100-240V 50/60Hz120VA
Dimensions 600mm x 360mm x 540mm ( 23.6""Hx14.2"Wx21.3""D)
Weight 49KG ( 108 lbs )
Rarcode Sanner QC Curve

 