GC MS Gas Chromatograph With Mass Spectrometer
Model: LTL-MSQ8100
GC1120 gas chromatograph
Features and performance:
1. Control system: designed for monitoring and controlling the instrument via the computer.
2. Column Compartment/oven with superior thermal performance, multistage (10 ramps) programmed temperature control function. (supported by “control system”)
3. Advanced built-in data acquisition system , supporting real time instrument status monitoring, detection signal acquisition and PC control
4. Column oven accommodates up to 3 chromatographic columns, and supports quick heat-up and rapid cool-down with automated back-door opening.
5. Flexible sample introduction system: 3 sample injectors could be installed and operated simultaneously with independent temperature control.
6. High sensibility and stability detector.
7. 2 independent and analog signals output.
8. M6 software, compatible with GLP/FDA-21 CFR Part11 requirements and regulations. (electronic records and signatures)
Accessories:
Carrier Gas System + Sample Introduction System + Separation System + Temperature Control System + Detector
Carrier Gas System: air source/ purification and desiccation device/ flow rate control device
Sample Introduction System: sample injector
Separation System: chromatographic column(packed column and capillary column)
Temperature Control System (Column Oven): constant temperature and programmed temperature
Detector: FID/ TCD/ FPD/ NPD
Main technical parameters:
Model#t | GC1120 | |
Sample Introduction System | sample injector and evaporation chamber | |
Column Oven | Temperature range |
Ambient temperature+7°C~400°℃(in 1°℃ increment) |
Temperature accuracy | ±0.02C | |
Cooling time | 40oC to 50°C in 8-10 min at 25°℃ ambient | |
Programmed temperature setting |
0.1°℃~40°C/min (in 1°C increment) | |
Program ramps |
7ramps in total (10 ramps available with control workstation) |
|
Size(LWH) | 284*280*241mm(inside) | |
Flame lonization Detector (FID) |
Detection limit | 3x101g/s(Cia) |
Best test result | 3x101g/s(Ci6) | |
Drift | 6x1013A/30min | |
Noise | $5x101A | |
Linearity range | z10 | |
Thermal Conductivity Detector (TCD) |
Sensitivity | 25000mV,mL/mg(C16) |
Baseline noise | 20uv | |
Drift | ≤60uV/h | |
Linearity range | 104 | |
Flame Photometric Detector (FPD) |
Detection limit | 8×101g/s(P); 8×1011g/s(S) |
Drift | 2×1011A/30min | |
Baseline noise | 5×101A | |
Nitrogen-Phosphorus Detector (NPD) |
Detection limit |
s5x10-12g/s(N)(Azobenzene) ≤5x10-13g/s(P)(Malathion) |