Patient monitor

  • Blood Pressure Holter 24h pm50
Blood Pressure Holter 24h pm50

Blood Pressure Holter 24h pm50

Blood Pressure Holter 24h

Model: PM50


 

Introduction

PM50 is a multifunctional patient monitor, it can monitor SPO2 and NIBP for a long time, and applies to the hospital wards or family daily health.
 
Features
   ◆Compact and portable, easy to use
   ◆With Integrative SpO2 Probe
   ◆Double working modes,monitoring function and 24 hours ambulatory NIBP measurement function can be flexibly set
   ◆NIBP and SPO2 can be monitored for a long time
   ◆NIBP and SPO2 data Record for large capacity
   ◆With friendly user interface, the user can see list menu and review measurement results
   ◆The device can display low power information, alarm information, error information and time information richly
   ◆Parameter alarms function is optional
   ◆Patient information can be flexibly set
   ◆Case management function.PC software can achieve data review, analysis measurement results, seeing trend, printing reports and other functions

 

 

 


Performance
   ◆NIBP           
       Measurement Method: Oscillometry
       Measurement Mode: The upper arm measure
       Measuring range: 
       ADULT:
       SYS  40mmHg270mmHg
       MAP  20mmHg235mmHg
       DIA  10mmHg215mmHg
       PEDIATRIC:      
       SYS  40mmHg200mmHg
       MAP  20mmHg165mmHg
       DIA  10mmHg150mmHg
       NEONATAL:   
       SYS  40mmHg135mmHg
       MAP  20mmHg110mmHg
       DIA  10mmHg100mmHg
       Automatic Measurement Interval: 5.10.15.20.30.45.60.90.120 minutes
       Resolution: 1mmHg
       Accuracy:  ±3mmHg
       Increasing pressure mode: force pump increases pressure automatically
       Reducing pressure mode: self-motion ladder reducing pressure mode
       Alarm parameter: SYS / MAP / DIA
   ◆SPO2       
       Measuring range: 0%100% (Resolution:1%) 
       Accuracy: 70-100%, ±2%, below 70% unspecified
       Error in Weak Filling Condition:
       SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).
       Resistance to surrounding light:
       The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.
   ◆Pulse Rate    
       Measuring range:0bpm250bpm
       Resolution:1bpm
       Accuracy: ±2 bpm or ±2% (select larger) 
   ◆Display: 2.4" TFT colour LCD
   ◆Power: DC 3VTwo "AA",1.5V Alkali Battery
   ◆Product safety type:Type BF application part (Internally powered,defibrillator protected)
 
Physics speciality
       Dimension: 128*69*36 mm (No including Packing)
       Weight: <350g (Including Batteries)
 
Accessories
   ◆cuff for adult
   ◆Integrative SpO2 Probe
   ◆USB data line
   ◆Disk (PC software) 
   ◆Pouch
   ◆User manual
 
Software function:
   ◆Up to 1000 patients cases can be edited and supervised.
   ◆The time segment of dealing with the patient’s NIBP data is 48 hours.
   ◆Connect the device by USB interface.
   ◆Can upload patient information data collection project and download collection data.
   ◆Can display scoop-shape trend graph,filling-type trend graph, histogram, pie chart, correlation line graph.
   ◆Can edit every piece of data, and add annotation to it.
   ◆Can edit basic information,doctor's advice information, NIBP and SpO2 status instruction, current medicine-taken information, etc.
   ◆Support print preview, print the report.

 